The Handi+ is everything it's always been and more! Maxtec has improved the Handi O2 analyzer to better meet your needs for oxygen analysis. The simple to use, one-touch calibration button, new overmold and calibration reminder combined with the traditional 2 year warranty, auto-off and size make ... [Full Description]

Configurations
Product NameProduct IdPriceQuantityAdd to Cart
16348$219.00
16359$219.00
back to top
Description
The Handi+ is everything it's always been and more! Maxtec has improved the Handi O2 analyzer to better meet your needs for oxygen analysis. The simple to use, one-touch calibration button, new overmold and calibration reminder combined with the traditional 2 year warranty, auto-off and size make it the best of its class. This analyzer is great for spot-checking O2 percentage in hospitals, clinics and in homecare environments.

Included with this model:

15mm Tee Adapter
Barbed Adapter w/ tubing
Flow Diverter
Lanyard
Handi+ Rubber Cover

* New and improved one-touch calibration button

* Overmold for extra protection

* Small, convenient and portable

* Auto-off

back to top
Specifications
  • Display Range: 0.0-99.9% oxygen
  • Display Resolution: 0.1% oxygen
  • Warm-up time: none required
  • Operating Temperature Range: 15-40 degrees C
  • Operating Humidity Range: 0-95% RH non-condensing
  • Accuracy: within 3% of full-scale over temperature range when calibrated at full scale.
    within 1% of full-scale at constant temperature, R.H. & pressure when calibrated at full scale
  • Sensor Type: galvanic fuel sensor 0-100% O2
  • Sensor Operating Life: 24 months under normal operating conditions
  • Sensor Shelf Life: 6 months
  • Storage Temperature: -15 to 50 degrees C
  • 90% Response Time: <15 Seconds @ 23 degrees C
  • Interference: Less than 2% of full-scale in presence of 75% Nitrous oxide
    Less than 2% of full-scale in presence of 5% Halothane
    Less than 2% of full-scale in presence of 5% Isoflurane
    Less than 2% of full-scale in presence of 5% Enflurane
    Less than 2% of full-scale in presence of 6% Sevoflurane
    Less than 2% of full-scale in presence of 15% Desflurane
    Less than 2% of full-scale in presence of 10% Carbon Dioxide
    Less than 2% of full-scale in presence of 70% Helium
  • Low-Battery Indicator: Display indicates E04
  • Power Requirement: Lithium button-cell battery, CR2450
  • Expected Operational Life: Approximately 1850 hours (74,000 cycles)
  • Instrument Weight: Approximately 3 ounces